email

Email:

info@CRMS.com

High-qualityProtein Sequencing

High-Resolution MS Molecular Weight Identification Service

At present, there are two types of mass spectrometry used for molecular weight analysis: Matrix-assisted laser desorption/ionization (MALDI-TOF) and Electrospray ionization (ESI-MS). The two methods have their own advantages and applications. MALDI-TOF can be used to directly measure the molecular weight of biopharmaceuticals, while ESI-MS analyzes multiple charge signals obtained by electric spray, and speculates the precise molecular weight through deconvolution. MALDI-TOF-MS is more suitable for analyzing biopharmaceuticals with molecular weight less than 25kDa. ESI-MS is recommended for molecular weight identification of protein substances with molecular weight of larger than 25kDa. MtoZ Biolabs has established a platform with both MALDI-TOF and ESI-MS technologies, which can be used to determine the molecular weight of all kinds of biopharmaceuticals, including antibodies, vaccines, proteins drugs, and polypeptides.

 

MtoZ Biolabs has established a platform with both MALDI-TOF and ESI-MS technologies, which can be used to determine the molecular weight of all kinds of biopharmaceuticals, including antibodies, vaccines, proteins drugs, and polypeptides.

Figure 1. MALDI-TOF Analysis of Biopharmaceuticals

 

MtoZ Biolabs has established a platform with both MALDI-TOF and ESI-MS technologies, which can be used to determine the molecular weight of all kinds of biopharmaceuticals, including antibodies, vaccines, proteins drugs, and polypeptides.

Figure 2. ESI-MS Analysis of Biopharmaceuticals

 

Sample Submission Requirements 

1. Sample Requirement

The sample should be dissolved in the volatile solvent with a low content of salt and detergent.

 

2. Requirement for Concentration of Detergents

 

pharm-molecular-weight-analysis3

 

3. Transportation of Samples

Freeze-dried protein samples, transported at frozen or 4 ℃.

 

Case Study

MALDI can analyze molecular weight of protein sample and the presence of polymers in protein or peptide segments in protein. The following is an actual result of determination of the molecular weight of a protein drug. We can see from the graph that there are dimers and trimmers existing in the protein sample.

 

MtoZ Biolabs has established a platform with both MALDI-TOF and ESI-MS technologies, which can be used to determine the molecular weight of all kinds of biopharmaceuticals, including antibodies, vaccines, proteins drugs, and polypeptides.

 

Deliverables 

1. Experiment Procedures

2. Parameters of Liquid Chromatography and Mass Spectrometer

3. MS Raw Data Files

4. Molecular Weight Results

5. Bioinformatics Analysis

 

Related Services

Identification of Biopharm

N/C Terminal Sequencing

Peptide Mapping

Amino Acids Composition

 

Variation Analysis

Glycosylation Site Analysis

Disulfide Bond Analysis

 

Purity Analysis

Purity Analysis SDS-PAGE

Purity Analysis SEC and RPLC

Host Cell Protein (HCP) Analysis

Antibody-Drug Conjugate (ADC) Analysis

Submit Inquiry
Name *
Email Address *
Phone Number
Inquiry Project *
Project Description*

 

How to order?